What this course covers
EBPHI NHIE — property & building inspection, analysis, reporting, business
Your exam and course scope
National Home Inspector Examination (EBPHI, ©2023 outline): 200 questions (175 scored + 25 pretest), 4 hours, scaled 200–800, pass = 500 (a scaled criterion cut, never a raw percent). Domain weighting: Property & Building Inspection 70% — the building-systems core and by far the deepest section, with electrical the #1 system, then roofing, structural, plumbing, and HVAC — then Analysis & Reporting 20% and Professional Responsibilities & Administration 10%. Hero surfaces: the electrical-defect trainer (grounding vs bonding, GFCI vs AFCI, FPE/Zinsco hazards, double-taps) and the confusable-pair discriminator tuned to the exact 70/20/10 blueprint — the fidelity even NHIE-specific apps drift from. Study where the 70% is, not InterNACHI's whole firehose.
Where this applies. This course prepares you for the National Home Inspector Examination (NHIE). Home inspector licensing is set by each state: some use the NHIE, some add a state exam (Texas, for example) or offer their own exam (New York), and some do not license inspectors, so confirm with your state regulator that the NHIE is your exam.
This is knowledge practice for the written exam. It does not replace approved training, eligibility checks, or any skills evaluation your certifying body requires. The NHIE exam fee, the EBPHI content-outline edition, the scaled-score model, and which states require the NHIE (plus each state's own licensing hours, CE, and business-law rules on top of the national exam) change over time and vary by jurisdiction — verify the current homeinspectionexam.org materials and your state licensing board before you register. The 500 pass mark is a scaled score, not a raw percentage; ignore any source presenting it as '62.5%'. Disregard older handbooks citing 160/40 items, a 0–100 scale, or 50/30/20 domain weights — those figures are superseded by the current 70/20/10 outline.
What you get
9 teaching modules and 56 practice questions, with narrated lessons, cards, explained answers and review of missed material. Review tests are drawn from the bank you drill and scored against a labelled practice readiness bar — a study target, not the official passing score and not a conversion to it.
How the real exam is scored. EBPHI scores the NHIE on a 200–800 scale with 500 to pass (175 scored questions plus 25 unscored pretest questions). The 500 is a scaled, criterion-referenced cut — never a raw percent correct.
Try the free lessons
Price and refund
One-time purchase, $39. No subscription. A refund request within 24 hours of purchase is handled by a person within one business day — write to support@passhomeinspector.com.
Sources and corrections
Teaching and narration are generated and reviewed against the references below; this is independent study material, not an official publication of any certifying body. Found an error? Write to support@passhomeinspector.com and we correct it.
- NHIE Content Outline Domain 1 Task 5.A · official
- 2024 IRC Chapter 36, service bonding and load-side isolation; NEC 250.24 / 250.32. Applicable adopted edition and existing-installation exceptions must be checked. · official
- NHIE Content Outline Domain 1 Task 5.C · official
- NHIE Content Outline Domain 1 Task 5.D: typical defects 'reverse polarity, open equipment grounds, non-functional GFCI or AFCI protection' · official
- NHIE Content Outline Domain 1 Task 5.B, items 8-9 · official
- NHIE Content Outline Domain 1 Task 5.E-F · official
- NHIE Content Outline Domain 1 Task 3 · official
- NHIE Content Outline Domain 1 Task 3.A · official
- NHIE Content Outline Domain 1 Task 4.A-D · official
- NHIE Content Outline Domain 1 Task 4.A: 'Water management (e.g., waterproofing, foundation drains, sump pumps)' · official
- NHIE Content Outline Domain 1 Task 4.B, D · official
- NHIE Content Outline Domain 1 Task 10.A: typical defects 'cross-connection, dissimilar metals, obsolete materials' + common problems 'galvanized piping' · official
- NHIE Content Outline Domain 1 Task 10.D · official
- NHIE Content Outline Domain 1 Task 10.C: 'Principles and usage of traps and vents' + typical defects 'inadequate venting, improper slope' · official
- NHIE Content Outline Domain 1 Task 12.A-B · official
- NHIE Content Outline Domain 1 Task 12: 'Chimney foundation, height, clearance requirements and terminations' + typical defects list · official
- NHIE Content Outline Domain 1 Task 13, items 1-2 · official
- NHIE Content Outline Domain 1 Task 13, items 3-4 · official
- NHIE Content Outline Domain 1 Task 1 · official
- NHIE Content Outline Domain 1 Task 2.A-B · official
- NHIE Content Outline Domain 1 Task 2.C-D: 'improper deck ledger attachment' + garage-door 'missing/misaligned/malfunctioning obstruction sensors, improper adjustment of automatic reverse' · official
- NHIE Content Outline Domain 1 Task 7 · official
- NHIE Content Outline Domain 1 Task 8.C (Vent Systems): safety issues 'back drafting/spillage, separated vent, venting too close to operable window' · official
- NHIE Content Outline Domain 1 Task 8.A · official
- NHIE Content Outline Domain 1 Task 8.B-C · official
- NHIE Content Outline Domain 1 Task 9: typical defects 'improper termination, plastic dryer ducts' · official
- NHIE Content Outline Domain 1 Task 6; official sample question 2 (candidate handbook, p.3): 'When a central air conditioning compressor is operating properly, [answer: B] the low pressure line is cold and the high pressure line is warm' · official
- NHIE Content Outline Domain 1 Task 11.A-C, E · official
- NHIE Content Outline Domain 2 Task 1 · official
- NHIE Content Outline Domain 2 Task 1, item 4 · official
- NHIE Content Outline Domain 2 Task 2 · official
- NHIE Content Outline Domain 2 Task 3, item 1 · official
- NHIE Content Outline Domain 2 Task 3, item 2 · official
- NHIE Content Outline Domain 2 Task 3, item 5 · official
- NHIE Content Outline Domain 2 Task 4, item 1: 'Qualified professional or tradesperson required to complete repairs or perform further evaluations' · official
- NHIE Content Outline Domain 2 Task 4, item 3 · official
- NHIE Content Outline Domain 3 Task 1 · official
- NHIE Content Outline Domain 3 Task 2 · official
- NHIE Content Outline Domain 3 Task 2, items 3-4 · official
- NHIE Content Outline (professional-responsibilities task cluster, cross-referenced against the structurally-consistent 2007-era outline's 'Professional Practice' Task 5 for completeness given the current outline's own extraction-risk on this domain — see VD-03) · official
- NHIE Content Outline (2023 RDS) Domain 1 Task 5.A ('Service and equipment grounding and bonding') + Task 5.B ('Panel grounding and bonding') + Task 5.D ('Equipment grounding and bonding') · official
- NHIE Content Outline Domain 1 Task 5.B ('circuit breakers and fuses, GFCI, AFCI') + Task 5.D ('AFCI and GFCI protection'; typical defect 'non-functional GFCI or AFCI protection'; safety issue 'absence of AFCI or GFCI') · official
- NHIE Content Outline Domain 1 Task 5.B, typical defects: 'double-tapping, over-fusing, loose connections' + safety issues 'multiple neutrals under one screw' · official
- NHIE Content Outline Domain 1 Task 5.B, item 8: 'Known problem electrical panel boards (e.g., Federal Pacific/Stab-Lok, Zinsco/Sylvania)' · official
- NHIE Content Outline Domain 1 Task 5.C: 'Considerations related to solid-conductor aluminum branch circuit wiring' + 'Outdated electrical wiring system (e.g., knob and tube wiring, cloth-covered cable)' · official
- NHIE Content Outline Domain 1 Task 4.A (Foundation): typical defects, soil types, applied forces, water management · official
- NHIE Content Outline Domain 1 Task 3 (A. Roof Coverings, B. Roof Drainage Systems, C. Roof Flashings, D. Skylights and Other Roof Penetrations) · official
- NHIE Content Outline Domain 1 Task 10.D (Water Heating Systems): 'typical defects (e.g., ... temperature pressure relief valve defects)' + safety issues 'lack of temperature/pressure relief valve, missing or improperly connected vents' · official
- NHIE Content Outline Domain 2 Task 3 ('Describe systems and components inspected that are not functioning properly or are defective') + Task 4 ('Describe systems and components in need of further evaluation or action') · official
- NHIE Content Outline Domain 2 Task 2: 'Describe the limitations in the inspection report to inform the client what was NOT inspected and why' · official
- NHIE Content Outline Domain 1 Task 7 (Heating): 'By-products of combustion (e.g., H2O, CO2, CO, NO2), their generation and how and when they become a safety hazard' + typical defects 'misfiring burner' + safety issues 'inadequate combustion air, loose flue connections, flame rollout' · official
- NHIE Content Outline Domain 1 Task 13: 'Smoke alarm and carbon monoxide alarm placement' + 'Egress requirements' + 'Fire suppression/sprinkler systems defects' · official
- nationalhomeinspectorexam.org/stateregulations/ + candidate handbook state-administrator list · official
- nationalhomeinspectorexam.org/frequently-asked-questions-2/ + /prepare-for-the-exam/ · official
- EBPHI Exam Overview packet (©2023) — 'How the Test Is Scored': raw score converted to a 200–800 scale, passing scaled score 500; no pass rate is given · reputable
- EBPHI Exam Overview packet (©2023), Content Outline — Domain 3: Professional Responsibilities (10%), Task 1 (5%) and Task 2 (5%) · official
- nationalhomeinspectorexam.org/stateregulations/ (adoption count only, not a full state-requirement table) · official