Pass Home Inspector

← NHIE study guide

Domain 1 — Property and Building Inspection/Site Review: NHIE topic guide

Domain 1 — Property and Building Inspection/Site Review carries 70% of the NHIE blueprint used in this course, the largest of its 3 weighted areas. It spans 20 concepts.

What Domain 1 — Property and Building Inspection/Site Review covers

  • Electrical service entrance components must be identified w... — NHIE Content Outline Domain 1 Task 5.A
  • Devices, equipment, and fixtures: typical defects include REVERSED POLARITY — NHIE Content Outline Domain 1 Task 5.D: typical defects 'reverse polarity, open equipment grounds, non-functional GFCI or AFCI protection'
  • Double-tapping/double-lugging and known-problem panel brands are BOTH named, distinct knowled... — NHIE Content Outline Domain 1 Task 5.B, items 8-9
  • Alternative-energy systems and electric-vehicle service equipment are named as their OWN task sub-items — NHIE Content Outline Domain 1 Task 5.E-F
  • Roofing is tested across FOUR named sub-categories: roof coverings, roof dr... — NHIE Content Outline Domain 1 Task 3
  • Foundation water management is named as its own foundation-task knowledge point — a founda... — NHIE Content Outline Domain 1 Task 4.A: 'Water management'
  • Floor and roof/ceiling structural defects — NHIE Content Outline Domain 1 Task 4.B, D
  • Water supply distribution materials carry different defect profiles: copper — NHIE Content Outline Domain 1 Task 10.A: typical defects 'cross-connection, dissimilar metals, obsolete materials' + common problems 'galvanized piping'
  • Drain-Waste-Vent systems rely on TRAPS and VENTS — NHIE Content Outline Domain 1 Task 10.C: 'Principles and usage of traps and vents' + typical defects 'inadequate venting, improper slope'
  • Fireplace/chimney inspection splits into SOLID-FUEL and GAS/LIQUID-FUEL appliance categories, ea... — NHIE Content Outline Domain 1 Task 12.A-B
  • Chimney height, clearance-to-combustibles, and termination requirements are explicitly named knowledge points — NHIE Content Outline Domain 1 Task 12: 'Chimney foundation, height, clearance requirements and terminations' + typical defects list
  • Egress requirements and fire/occupancy se... — NHIE Content Outline Domain 1 Task 13, items 1-2
  • Smoke-alarm and CO-alarm placement plus fire-suppression/sprinkler-system defects — NHIE Content Outline Domain 1 Task 13, items 3-4
  • Site-level inspection covers vegetation/grade/drainage/retaining walls — NHIE Content Outline Domain 1 Task 1
  • Deck/balcony/stair ledger-board attachment is a NAMED life-safety defect category
  • Heating-system inspection requires understanding the PRINCIPLES of the system's operation — connections to an... — NHIE Content Outline Domain 1 Task 7
  • Combustion air requirements and vent-system operation — NHIE Content Outline Domain 1 Task 8.C: safety issues 'back drafting/spillage, separated vent, venting too close to operable window'
  • Mechanical exhaust systems and indoor-air-management systems are a ... — NHIE Content Outline Domain 1 Task 9: typical defects 'improper termination, plastic dryer ducts'
  • Central air-conditioning/heat-pump cooling operation follows the refrigerant cycle — NHIE Content Outline Domain 1 Task 6
  • Interior defects split into those CAUSED by other systems — NHIE Content Outline Domain 1 Task 11.A-C, E

Official references for Domain 1 — Property and Building Inspection/Site Review

  • NHIE Content Outline Domain 1 Task: 5.A, 5.C, 5.E-F, 3, 4.A-D, 10.D, 12.A-B, 1, 2.A-B, 7, 8.A, 8.B-C, 6, 3.A
  • NHIE Content Outline Domain 1 Task 5.B: 'Panel grounding and subpanel neutral isolation'
  • NHIE Content Outline Domain 1 Task 5.D: typical defects 'reverse polarity, open equipment grounds, non-functional GFCI or AFCI protection'
  • NHIE Content Outline Domain 1 Task 5.B, items: 8-9
  • NHIE Content Outline Domain 1 Task 4.A: 'Water management'
  • NHIE Content Outline Domain 1 Task 4.B, D
  • NHIE Content Outline Domain 1 Task 10.A: typical defects 'cross-connection, dissimilar metals, obsolete materials' + common problems 'galvanized piping'
  • NHIE Content Outline Domain 1 Task 10.C: 'Principles and usage of traps and vents' + typical defects 'inadequate venting, improper slope'
  • NHIE Content Outline Domain 1 Task 12: 'Chimney foundation, height, clearance requirements and terminations' + typical defects list
  • NHIE Content Outline Domain 1 Task 13, items: 1-2, 3-4
  • NHIE Content Outline Domain 1 Task 8.C: safety issues 'back drafting/spillage, separated vent, venting too close to operable window'
  • NHIE Content Outline Domain 1 Task 9: typical defects 'improper termination, plastic dryer ducts'

In the app this area comes with 28 module-quiz questions in the full course.

Start the free NHIE modules →